Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMJ Open ; 14(3): e080103, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38443085

RESUMO

OBJECTIVE: To compare the efficacy and safety of different anti-vascular endothelial growth factor (VEGF) agents combined with different delivery methods for neovascular glaucoma (NVG). DESIGN: Systematic review and Bayesian network meta-analysis (NMA). DATA SOURCES: PubMed, Embase, Cochrane Library, Web of Science, ClinicalTrials.gov, ISRCTN and Chinese databases including the China National Knowledge Infrastructure, China Science Periodical Database (Wanfang Database), VIP Journal Integration Platform and China Biology Medicine Database were searched from inception to 5 September 2022. ELIGIBILITY CRITERIA: We included randomised controlled trials (RCTs) that investigated the treatment of NVG using different anti-VEGF agents combined with various methods of drug administration, without any language limitations. All patients included underwent panretinal laser photocoagulation and there were no restrictions on prior glaucoma surgery. DATA EXTRACTION AND SYNTHESIS: Two independent reviewers extracted data and assessed the risk of bias. Random-effect Bayesian NMA was conducted to compare the efficacy and safety and rank priority of anti-VEGF regimens. The source of heterogeneity and the related factors affecting the stability of the results were also explored. CINeMA (Confidence in Network Meta-Analysis) was used to assess the certainty of evidence. RESULTS: Our analysis included 17 RCTs involving a total of 1311 eyes from 1228 patients. We examined five different treatment regimens, which used three different anti-VEGF drugs. The following treatments showed a significant decrease in intraocular pressure (IOP) compared with the control group at 1 month after glaucoma surgery: simultaneous intravitreal and intracameral injection of conbercept (ICCIVC) (mean difference (MD)=-11.56, 95% credible interval (CrI) -20.8 to -2.24), intravitreal injection of conbercept (MD=-8.88, 95% CrI -13.93 to -3.78), intravitreal injection of ranibizumab (MD=-7.62, 95% CrI -10.91 to -4.33) and intravitreal injection of bevacizumab IVB) (MD=-5.51, 95% CrI -10.79 to -0.35). The surface under the cumulative ranking curve (SUCRA) analysis indicated that ICCIVC (82.0%) may be the most effective regimen in reducing IOP. In terms of safety, there were no statistically significant differences among the interventions. According to the SUCRA analysis, ICCIVC (68.0%) was considered the safest choice with the fewest complications. Subgroup and meta-regression analyses showed that mean age was the main source of heterogeneity. Sensitivity analysis demonstrated the robustness of the study results. CONCLUSION: ICCIVC was more effective and safer than other anti-VEGF regimens for NVG. Simultaneous intravitreal and intracameral injection was found to be the best route of administration, and conbercept was found to be the superior drug selection when compared with ranibizumab and bevacizumab. PROSPERO REGISTRATION NUMBER: CRD42022309676.


Assuntos
Glaucoma Neovascular , Glaucoma , Humanos , Glaucoma Neovascular/tratamento farmacológico , Bevacizumab/uso terapêutico , Metanálise em Rede , Ranibizumab , Fatores de Crescimento do Endotélio Vascular
2.
Int J Ophthalmol ; 16(11): 1845-1853, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028513

RESUMO

AIM: To assess the visual correction of patients with different degrees of astigmatism with toric soft contact lenses (TSC). METHODS: It was a real-world study with prospective and single-arm design. A total of 384 patients with astigmatism who came for TSC fitting and alignment from November 2022 to January 2023 were included. According to the difference in astigmatism, patients were divided into groups A (cylinder degree: -0.75 to -0.50 D), B (cylinder degree: -1.75 to -1.00 D) and C (cylinder degree ≤ -2.00 D), and followed up on the day of wear, 1wk, 1 and 3mo, mainly to observe visual acuity, refraction, lens fit, visual quality and comfort at 1wk after wear. The visual acuity success rate and the overall success rate of the fitting were evaluation indicators (taking into account the four dimensions of visual acuity, fitting, quality of vision and comfort). The visual acuity success rate was calculated by taking "corrected visual acuity with contact lenses is no less than 1 line or better than best spectacle-corrected visual acuity" (i.e. corrected visual acuity with contact lenses is 1 line below, equal to, one line above or more than best spectacle-corrected visual acuity) as the criterion for visual success, and the the overall success rate of the fitting was calculated by using the comprehensive indicators (visual acuity, fit, visual quality, comfort) to meet certain conditions as the judgment criteria for successful fitting. RESULTS: After 1wk of wearing TSC, the visual acuity success rates of patients were 100% (207/207), 98.58% (139/141) and 97.22% (35/36) in the three groups, respectively, with residual cylinder closed to 0. The acceptability of the lens fitting was over 95%; the incidence of adverse visual symptoms was within 10% and the comfort acceptability was over 97%. The overall success rate of fitting for patients with high, medium and low astigmatism was 93.72% (194/207), 90.78% (128/141) and 88.89% (32/36), respectively. CONCLUSION: TSC (model: G&G POP·CT) are effective in correcting astigmatism in patients with different degrees of astigmatism.

3.
Small ; 19(2): e2204719, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36333119

RESUMO

As the leading cause of death, heart attacks result in millions of deaths annually, with no end in sight. Early intervention is the only strategy for rescuing lives threatened by heart disease. However, the detection time of the fastest heart-attack detection system is >15 min, which is too long considering the rapid passage of life. In this study, a machine learning (ML)-driven system with a simple process, low-cost, short detection time (only 10 s), and high precision is developed. By utilizing a functionalized nanofinger structure, even a trace amount of biomarker leaked before a heart attack can be captured. Additionally, enhanced Raman profiles are constructed for predictive analytics. Five ML models are developed to harness the useful characteristics of each Raman spectrum and provide early warnings of heart attacks with >98% accuracy. Through the strategic combination of nanofingers and ML algorithms, the proposed warning system accurately provides alerts on silent heart-attack attempts seconds ahead of actual attacks.


Assuntos
Infarto do Miocárdio , Análise Espectral Raman , Humanos , Análise Espectral Raman/métodos , Infarto do Miocárdio/diagnóstico , Aprendizado de Máquina , Algoritmos
4.
Front Neurosci ; 15: 683153, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34163327

RESUMO

PURPOSE: The current study was to investigate whether myopia affected peripheral motion detection and whether the potential effect interacted with spatial frequency, motion speed, or eccentricity. METHODS: Seventeen young adults aged 22-26 years participated in the study. They were six low to medium myopes [spherical equivalent refractions -1.0 to -5.0 D (diopter)], five high myopes (<-5.5 D) and six emmetropes (+0.5 to -0.5 D). All myopes were corrected by self-prepared, habitual soft contact lenses. A four-alternative forced-choice task in which the subject was to determine the location of the phase-shifting Gabor from the four quadrants (superior, inferior, nasal, and temporal) of the visual field, was employed. The experiment was blocked by eccentricity (20° and 27°), spatial frequency (0.6, 1.2, 2.4, and 4.0 cycles per degree (c/d) for 20° eccentricity, and 0.6, 1.2, 2.0, and 3.2 c/d for 27° eccentricity), as well as the motion speed [2 and 6 degree per second (d/s)]. RESULTS: Mixed-model analysis of variances showed no significant difference in the thresholds of peripheral motion detection between three refractive groups at either 20° (F[2,14] = 0.145, p = 0.866) or 27° (F[2,14] = 0.475, p = 0.632). At 20°, lower motion detection thresholds were associated with higher myopia (p < 0.05) mostly for low spatial frequency and high-speed targets in the nasal and superior quadrants, and for high spatial frequency and high-speed targets in the temporal quadrant in myopic viewers. Whereas at 27°, no significant correlation was found between the spherical equivalent and the peripheral motion detection threshold under all conditions (all p > 0.1). Spatial frequency, speed, and quadrant of the visual field all showed significant effect on the peripheral motion detection threshold. CONCLUSION: There was no significant difference between the three refractive groups in peripheral motion detection. However, lower motion detection thresholds were associated with higher myopia, mostly for low spatial frequency targets, at 20° in myopic viewers.

5.
ACS Appl Mater Interfaces ; 13(6): 7672-7679, 2021 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-33512139

RESUMO

Aluminum (Al) can actively support plasmonic response in the ultraviolet (UV) range compared to noble metals (e.g., Au, Ag) and thus has broad applications including UV sensing, displays, and photovoltaics. High-quality Al films with no oxidation are essential and critical in these applications. However, Al is very prone to fast oxidation in air, which critically depends on the fabrication process. Here, we report that by leveraging the in situ sputter etching and sputter deposition of a 1 nm tetrahedral amorphous carbon (ta-C) film on the Al nanostructures, Al plasmonic activity can be improved. The prior sputter etching process greatly reduces the oxidized layer of the Al films, and the subsequent sputter deposition of ta-C keeps Al oxidation-free. The ta-C film outperforms the naturally passivated Al2O3 layer on the Al film because the ta-C film has a denser structure, higher permittivity, and better biocompatibility. Therefore, it can effectively improve the plasmonic response of Al and be beneficial to molecule sensing, which is proved in our experiments and is also verified in simulations. Our results can enable the various applications based on plasmon resonance in the UV range.

6.
Invest Ophthalmol Vis Sci ; 61(8): 1, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32609295

RESUMO

Purpose: The purpose of this study was to present our investigation of the influence of reduced monocular luminance on monocular and dichoptic temporal synchrony processing in healthy adults. Methods: Ten adults with normal or corrected to normal visual acuity participated in our psychophysical study. The temporal synchrony threshold in dichoptic (experiment 1), monocular (experiment 2), and binocular (experiment 3) viewing configurations was obtained from each observer. Four flickering Gaussian dots (one synchronous and one asynchronous pair of two dots) were displayed, from which the observers were asked to identify the asynchronous pair. The temporal phase lag in the signal pair (asynchronous) but not in the reference pair (synchronous) was varied. In addition, a neutral density (ND) filter of various intensities (1.3 and 2.0 log units) was placed before the dominant eye throughout the behavioral measurement. In the end, dichoptic, monocular, and binocular thresholds were measured for each observer. Results: With decreasing monocular luminance, the dichoptic threshold (2 ND vs. 0 ND, P < 0.001; 2 ND vs. 1.3 ND P = 0.001) and monocular threshold (2 ND vs. 0 ND, P < 0.001; 2 ND vs. 1.3 ND, P = 0.003) increased; however, the bincoular threshold remained unaffected (P = 0.576). Conclusions: Reduced luminance induces delay and disturbs the discrimination of temporal synchrony. Our findings have clinical implications in visual disorders.


Assuntos
Sensibilidades de Contraste/fisiologia , Potenciais Evocados Visuais/fisiologia , Limiar Sensorial/fisiologia , Lobo Temporal/fisiologia , Visão Monocular/fisiologia , Adulto , Feminino , Humanos , Masculino , Estimulação Luminosa , Psicofísica , Valores de Referência
7.
eNeuro ; 7(3)2020.
Artigo em Inglês | MEDLINE | ID: mdl-32345735

RESUMO

Action video gaming can promote neural plasticity. Short-term monocular patching drives neural plasticity in the visual system of human adults. For instance, short-term monocular patching of 0.5-5 h briefly enhances the patched eye's contribution in binocular vision (i.e., short-term ocular dominance plasticity). In this study, we investigate whether action video gaming can influence this plasticity in adults with normal vision. We measured participants' eye dominance using a binocular phase combination task before and after 2.5 h of monocular patching. Participants were asked to play action video games, watch action video game movies, or play non-action video games during the period of monocular patching. We found that participants' change of ocular dominance after monocular patching was not significantly different either for playing action video games versus watching action video game movies (Comparison 1) or for playing action video games versus playing non-action video games (Comparison 2). These results suggest that action video gaming does not either boost or eliminate short-term ocular dominance plasticity, and that the neural site for this type of plasticity might be in the early visual pathway.


Assuntos
Jogos de Vídeo , Adulto , Dominância Ocular , Humanos , Plasticidade Neuronal , Visão Monocular , Vias Visuais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...